Laminar / In-house test teams
You test the cleanrooms. Laminar does the paperwork.
Locations, sample volumes and the certificate, worked out from the field record.
- No certifier needed
- ISO 1 to 9
- First job free
- Locations
- 9
- Min. sample
- 5.68 L
- Taken
- 28.3 L
Every round
More testing, the same stretched team.
Today
- Table A.1, redone by hand
- Counts, calibrations, certificates: three folders
- “Show us the as-found count.”
With Laminar
- Locations worked out for every room
- One record per room
- As found kept beside the retest
In the bay
Typed once. Checked as it goes in.
One reading at a time on the iPad, offline if need be. Or paste rows from the counter.

The certificate
ISO 14644-1, every clause shown.
Built from the field record. Ready for your own reviewer.
ISO 7
PassSend us your last two rounds.
Free gap check on your own spreadsheets. NDA first, back in 5 business days.
Fair questions
Before you change a workflow.
Criteria built from
- ISO 14644-1
- ISO 14644-3
- USP <797>
- USP <800>
- EU GMP Annex 1
- IEST-RP-CC034
Our counters already log data. Do we retype every count?
No. Paste rows from any counter's printout or a .csv, .txt or .tsv export: Laminar turns them into readings your technician confirms. Or type each count once on the iPad, with the counter and its calibration attached. Either way Laminar checks the location count, sample volume and time against ISO 14644-1, and the counter's own export stays your raw data.
Show me the arithmetic.
Bay 3, ISO 5, 36 m², counted at 0.1 and 0.5 µm: Table A.1 gives 9 locations (A.4.1). The limit at 0.5 µm is 3,520 /m³ and at 0.1 µm 100,000 /m³ (Table 1). The minimum single sample is 20 / 3,520 × 1000 = 5.68 L (A.4.4); one minute at 28.3 L/min takes 28.3 L: met. Every sample is at least 2 L and at least 1 minute. Laminar does this for every room and checks each count as it goes in.
Do we need a certifier to use it?
No. Your own trained team tests and your own reviewer reviews and signs. Laminar keeps the method, instrument, calibration and criteria behind every result.
Which classes and sizes?
Every class from ISO 1 to ISO 9, at 0.1, 0.2, 0.3, 0.5, 1 and 5 µm, plus airflow and air changes, room pressure differentials, installed HEPA filter leak tests and recovery in the same record. Sizes are picked per room.
More questions (6)
Does this replace our environmental monitoring system?
No. Laminar handles periodic classification, requalification and filter testing: the plan, the field record, the certificate and the history. Your continuous monitoring system keeps doing continuous monitoring.
How do you handle data integrity for pharma QC?
Every entry records who, when and with which instrument. Originals are never overwritten, and every retest or correction carries a written reason. The sign-off names the reviewer, the time and a written statement, bound to the exact report revision, and every issued report is a frozen, hashed snapshot. Sign-in is role-based (admin, reviewer, technician), and the full audit trail exports as CSV or Excel.
Can we bring our spreadsheets in?
Upload a room list or last round's spreadsheet and Laminar proposes your rooms and test plan for you to review, every assumption marked for one-tap confirmation. Data out, any time: PDF, CSV, the audit trail as Excel and audit bundles (.zip).
Will it get through our supplier qualification?
Send it to us and see: sign-in limited to your organization's staff plus the report readers you grant, full export at any time, encrypted hosting with 30-day point-in-time recovery, and the complete audit trail. Email your questionnaire to marketing@laminarcert.com and get every answer in writing.
What happens to our records long term?
They are yours, always. Every report prints to PDF and every reading exports to CSV at any time, without asking us, and your signed reports stay wherever you file them today. Send your supplier questionnaire and get every answer in writing.
What does it cost?
The report gap check is free. Your first job on Laminar is free, with no commitment. After that, Laminar is priced per room or per visit, quoted for your rooms on the call. No setup fee: we build your facility from your drawings and past reports.
Talk to us
See Laminar run your own rooms.
Thirty minutes, live, set up around how your team tests. Bring a room list.
Book a 30-minute callor send the form and we reply within one business day.
David WeilFounder · a named person, not a ticket queue
- 1 business dayReply, guaranteed
- NDA firstBefore any report
- First job freeNo commitment
Gap check back in 5 business days · Reports deleted within 30 days · Originals never overwritten
Got it — thank you.
We reply within one business day, the way you asked. Emails come from marketing@laminarcert.com; add it to your contacts so it doesn't land in spam.
Urgent? Call +1 (704) 500-8100 and mention your facility.